Ronan X55-600 Series Manuale Utente Pagina 3

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 2
input signal, i.e., when the input signal
increases toward full scale, the output pres-
sure decreases toward the zero value.The
SPLIT/FULL switch, when in the SPLIT posi-
tion, causes a full scale change in the output
pressure for a 50% change of the normal
input span, e.g., a 3-15 psig output change in
response to a 4-12 or 12-20 mA input
change.
2.0 SPECIFICATIONS
Air Consumption: 0.002 SCFM.
Supply Pressure Effect: None.
Supply Pressure: 5-120 psi (min. = output
+5 psi.)
Loop Voltage Drop: <6 VDC (at 4-20 mA
input).
Output Ranges: 3-15, 3-27, 6-30, 0-60, 0-
100 psi. For other zero based and high out-
put pressure ranges contact Ronan.
Accuracy: ±0.20% of span includes linearity,
hysteresis, and repeatability.
Zero and Full Scale Adjustability: >±12%
of span.
Input Range: 4-20, 10-50 (switch selec-
table), 0-10 Vdc available - contact Ronan.
Operating Modes: Direct, reverse, or split
range (switch selectable)
Mounting Position Effect: None.
Vibration Effects: <±1.0% of span at ±1.0
g’s from 5-2 KHz.
RFI/EMI Effects: <0.8% of range with 5 Watt
transmitter at 1 meter (20 to 500 MHz).
Shock Effects: ±3% of span at 30 g’s.
Operating Temp.: -20 to +150°F (-11 to 65°C).
1.0 GENERAL DESCRIPTION
The Ronan Model X55-600 I to P Transducer
accepts a 4-20 or 10-50 mA control signal
input and provides a regulated pressure out-
put. The input current range is selectable by
a switch located on the top of the module.
The input pressure may be in the range of 20
to 120 psig and at least 5 psig above the
maximum output pressure. The Model X55-
600 utilizes solid-state technology and output
pressure sensing to provide a high degree of
accuracy. A closed loop feedback system is
utilized to condition the mA input current into
a voltage which is applied to one input of a
control comparator. The comparator output
causes the control voltage on a piezo-ceram-
ic beam to bend the beam in a manner that
results in, more or less, back pressure on a
balanced diaphragm and spring valve control
assembly. As the output pressure responds
to a change in the input signal, it is sensed
by a pressure sensor whose electrical output
is conditioned and applied to the second
input of the control comparator. When this
pressure feedback signal is equal to the con-
ditioned input signal, the output pressure has
changed to the desired value and the system
remains in this state until the input mA signal
is changed to a new value.
The piezo-ceramic beam is a very delicate
device designed for extremely small move-
ments in proportion to the signal applied.
Attempting to deflect the beam manually will
result in a damaged or broken beam, which
is not covered under warranty.
Other switch-operated controls located at the
top of the module are a DIR/REV (direct/
reverse) switch and a SPLIT/FULL switch.
The DIR/REV switch, in the REV position,
inverts the output signal with respect to the
1