Ronan X55-600 Series Manuale Utente Pagina 8

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 7
eventually cause corrosion damage to
the I/P.
Coalescing filters is an inexpensive way to
help prevent I/P malfunctions or failures.
These filters remove particles and moisture
from air lines.
2) Oil in the supply air usually is from the
main compressor. Oil can clog the small
nozzles and disturb the normal opera-
tion of the I/P-converter. The result is
poor control or in the worst case, failure.
3) Particles in the air usually occur
because of corrosion. Dirt and particles
can block the small nozzles of the I/P
converter.
To en s ur e no rma l op er at io ns , we r ec omm e nd
that a water separator and a 5 micrometer fil-
ter are mounted as close to the I/P as possi-
ble. If oil is present, an oil separator should
be installed as well.
We recommend that the working air is clean,
dry and free of moisture, water, oil, particles
and other contaminants, in accordance with
the international standard ISA S7.3-181.
to increase or counterclockwise to
decrease the setting to within the recom-
mended range.
10. Repeat steps eight and nine until satis-
fied.
11. Remove calibration wires. Reinstall gray
cover from step 6.
12. Reattach calibration wires and do one
final zero/span and power failure check.
13. Reattach field wiring, NEMA 4, explo-
sion-proof covers (if appropriate).
Air Quality Recommendations
Poor air quality is one of the causes of pre-
mature functionally problems with pneumatic
and electro-pneumatic equipment.
1) Water in the supply air is a natural
occurrence. When the air cools in pipes,
etc., the moisture condenses and
becomes liquid water. This water will
6
Printed in the U.S.A.
Figure 1.
–+G
Input
Ter mi na ls
Air
Inlet
Air
Outlet
0 mA
Air Pin
Vedere la pagina 7